98329010 Rev-A
Elkhart Brass Mfg. Co., Inc. 1302 W. Beardsley Avenue • Elkhart, Indiana 46514 • 1-574-295-8330 • 1-800-346-0250
www.elkhartbrass.com
Using a UBEC1C to control an E3F or E5F actuated valve
Refer to Unibody valve installation and instruction manual p/n 99329000.
The manual can be found online at www.elkhartbrass.com
The UBEC1C controller is designed to control an E3F or E5F actuated valve. The
UBEC1C must be wired for CAN communication with an E3F or E5F actuated valve.
Part number 08899152 includes a UBEC1C controller with harnessing for connecting
controller power and CAN communication.
Installation; see section lV, page 6 of the manual.
Wiring; Figure 1 shows the harness required for controller power and communication
between the UBEC1C and the E3F or E5F. The 6 pin connector on this harness plugs
into the mating connector of the UBEC1C controller. Connect the red (+) & black (-)
wires of this harness to 1 amp fused 12v (or 0.5 amp fused 24v) truck power & ground
using the heat shrinkable crimp connectors. The harness in figure 2 shows the harness
for CAN communication with the E3F or E5F actuator. It connects to its mating
connector on the figure 1 harness and has three leads ending with heat shrinkable
crimp connectors. The harness in figure 3 is included with the actuator. The 12 pin
connector on the harness plugs into the top of the E3F or E5F actuator. Connect the red
(+) & black (-) wires of this harness to 30 amp fused 12v (or 15 amp fused 24v) truck
power & ground using the heat shrinkable crimp connectors. The 2 pin Packard
connector will plug into its mating connector on the lead from the actuators electric
motor. This harness also includes a connector for CAN communication (Figure 2) that
has three leads ending with heat shrinkable crimp connectors. Use 18-22 ga wire to
interconnect the CAN connectors at the E3F or E5F actuator and UBEC1C controller.
Connect green to green, blue to blue, and black to black. Maintaining wire color code
will greatly reduce risk of errors. Crimp the connectors securely onto the stripped wires
and use a heat gun to shrink and seal the connections.
Final wiring check; Check that all unused connector positions have seal plugs in them,
that wires are in the correct positions in their connectors, and that their contacts are
locked securely into the connectors and can not come back out.